Faults

Fault table

Fault Cause Behaviour
Low field strength The magnetic field is too weak, or there is no magnet. The throttle sends 0° and 0%, and sets the applicable status bits.
Redundancy fault The two redundant sensors do not agree. The throttle sends 0° and 0%, and sets the applicable status bits.
Sensor link fault The internal sensor communication stopped. The throttle sends 0° and 0%, and sets the applicable status bits.
Sensor internal fault An internal fault in a sensor. There are many possible causes. The throttle sends 0° and 0%, and sets the applicable status bits.
Travel bounds fault The angle is outside the calibrated dead bands. The throttle sends the measured and calibrated angles as usual, but sends 0% relative travel. It sets the applicable status bits.

Throttle faults

For the status bits, refer to Status bit field.

Clearing faults

To clear the faults, do one of these steps:

  • Turn the throttle off and on again.
  • Write 0x2FFF to index 0x3001, sub-index 0x3E (Special Commands).