This guide tells you how to set up an ASI BAC6 controller from the evaluation kit with your battery and motor. You use BACDoor®3. At the end, the motor operates from a throttle. Each step gives the basic actions and a link to the reference page for more information.
Critical Safety Instructions
Make sure that only a trained technician installs or sets up the Accelerated Systems controller. If you do not obey these instructions, damage to the controller, the computer, or the vehicle can occur. These hazards can also cause injury or kill you.
Before you connect, set up, or operate the controller, read these instructions:
- Wear the applicable personal protective equipment (PPE) near batteries and moving parts.
- Use insulated tools. Insulated tools prevent electrical shock.
- Always connect a USB isolator between the computer and the controller. If you do not use a USB isolator, damage to the computer or the controller can occur. ASI is not responsible for this damage.
- Before you make connections, make sure that the battery or power source is disconnected or set to OFF.
- Make sure that the area around the vehicle is clear. Keep all persons and animals away from the vehicle during tests and operation. The motor turns during setup and tests.
- Before you do a test of the motor or vehicle, put the vehicle on a stand. Use an approved bike stand or automotive jack stands. Make sure that the wheels do not touch the ground.
- As an alternative, attach the motor to a workbench vise or a solid stand. This holds the motor in position during tests.
- Make sure that all moving parts (for example, pedals and wheels) can turn freely in the two directions.
Before you start
Tools required
- Personal protective equipment (PPE), for example safety glasses and gloves.
- Insulated hand tools, for example wrenches and screwdrivers.
- A stand for the vehicle or motor, for example a bike stand or jack stands. The stand must hold the wheels off the ground.
- A crimper for the motor and battery connectors.
- A torque wrench (high-power controllers).
- A computer with BACDoor®3 installed, and an ASI account to sign in.
What is in the evaluation kit
- The controller.
- The evaluation harness.
- A USB-TTL serial cable.
- A USB isolator and USB cable.
- High-power controllers: the mounting hardware that Wire the controller gives.
Required system information
Get this information before you start. If you cannot find a value, ask your battery or motor manufacturer.
| Information | Description | Where to find it |
|---|---|---|
| Rated system voltage (V) | The nominal battery voltage, for example 48 V. Not the fully charged or cutoff voltage. | Battery datasheet |
| Battery peak current (A) | The maximum current the battery can supply. | Battery datasheet |
| Rated motor power (W) | The maximum electrical power you allow the motor to draw. Not the continuous power. Do not set it higher than the battery peak power (rated system voltage × battery peak current). | Motor and battery datasheets |
| Rated motor current (A) | The rated peak phase current of the motor. | Motor datasheet |
| Rated motor speed (RPM) | The no-load speed of the motor at the rated system voltage. For a geared motor, multiply the output speed by the gear ratio. | Motor datasheet |
| Motor position sensor | Hall sensors, sine-cosine encoder, or none (sensorless). | Motor datasheet |
| Motor pole pairs | The number of magnets in the rotor divided by 2. | Motor datasheet |
| Gear ratio | Motor revolutions per wheel revolution. For a direct-drive motor, use 1. | Motor datasheet |
Required system information
For these terms, refer to the Glossary.
Wire the controller
WARNING
Make sure that your electrical system has these items:
- A battery management system (BMS) that operates correctly
- A fuse with the correct size
- The correct wire gauge
- A pre-charge circuit
- A safety cutoff switch
Refer to Protections & fusing.
DANGER
- Make sure that voltage and current spikes are not more than the input or output ratings of the controller.
- Use the controller only in battery-powered systems. It is designed only for these systems.
Do not connect battery positive (B+) now. You connect it in a subsequent step, in Connect the computer and power up.

Low-power controllers
-
Crimp the bullet connectors to the motor phase wires and the battery wires.


Bullet connectors
-
Connect battery negative to the black wire of the controller (A).
- Connect the evaluation harness to the controller connector (B).
- Connect the motor phases (C): green to phase A, yellow to phase B, blue to phase C. Do not connect the red B+ wire yet.
- Install the key-in jumper in the evaluation harness (D).

Low-power wiring

Low-power controller wires

High-power controller DC input terminals, 3-phase output terminals and 16-pin Molex connector
| Item # | Description | QTY | BAC2000 | BAC4000 | BAC8000 |
|---|---|---|---|---|---|
| 5 | Controller Clip | 4 | x | x | x |
| 6 | M5 x 12mm Hex Head | 5 | x | x | |
| 7 | M5 Lock Washer | 5 | x | x | |
| 8 | M5 Flat Washer | 5 | x | x | |
| 9 | M6 x 14mm Hex Head | 5 | x | ||
| 10 | M6 Lock Washer | 5 | x | ||
| 11 | M6 Flat Washer | 5 | x |
Included hardware (x is included)
- Crimp ring terminals to the 3 motor phase wires.
- Attach battery negative to the controller negative (−) terminal.
- Connect the evaluation harness to the 16-pin Molex connector.
- Attach the 3 motor phase wires to the U, V, and W terminals.
Install the hardware in this sequence: bolt, lock washer, flat washer, then the wire terminal at the bottom. Use a torque wrench to tighten the bolts:
- BAC2000 and BAC4000: 6 N·m (53 in·lb)
- BAC8000: 8 N·m (70 in·lb)
Do not torque the bolts more than these values.

Terminal hardware and torque
Connect the computer and power up
WARNING
Always connect the USB isolator between the computer and the controller. If you do not use a USB isolator, damage to the computer or the controller can occur.
- Connect the USB-TTL cable to the TTL connector on the evaluation harness (A).
- Connect the other end of the USB-TTL cable to the USB isolator (B).
-
Connect the USB isolator to the computer with the USB cable (C, D). Wait until the computer installs the drivers.

Computer connections
-
Make sure that the battery has a pre-charge or soft-start function, or that you installed a pre-charge circuit. The evaluation kit does not include a pre-charge circuit. If there is no pre-charge, the inrush current can trip the battery BMS when you connect B+. It can also cause damage to the controller or the battery. Refer to Capacitor inrush current protection.
-
Connect battery positive (B+) through your pre-charge circuit:
Connect battery positive to the red wire of the controller (F).

Attach battery positive and the pin 9 (Key In) wire of the harness to the controller positive (+) terminal.
-
If the battery has a power switch, turn it on. Look at the controller status LED.



- If the LED is on and does not flash, the controller is ready.
- If the LED flashes, there is a fault. Count the flashes and refer to Faults and warnings.
- If the LED is off, the controller has no power. Examine all the connections, the cables, and the battery.
Connect BACDoor®3
- Open BACDoor®3. Sign in.
- In the Connection view, make these settings:
- Set Type to TTL.
- Select the Port of the USB-TTL cable.
- Set Baud Rate to 115200.
-
Click Connect. If BACDoor®3 does not connect, refer to Connection troubleshooting.

Connection view when connected
- Look at the Faults and Warnings view. It is usual to see some warnings until you complete the setup.
In the subsequent steps, you change parameters on the Advanced Setup page. To change a value, type it and press Enter, or select it from the drop-down list. Each page has three panels:
- The upper-left panel shows parameters that you can save to flash.
- The lower-left panel shows temporary parameters. You cannot save them, and the controller does not keep them at power off.
- The Display Only panel on the right shows read-only values.
BACDoor®3 writes each value to the controller immediately. But the controller keeps the value after power off only when you click Save to Flash. For more information, refer to the BACDoor®3 user guide.
Save a backup parameter file
WARNING
Make a backup of the original parameters before you change a parameter. You must have this file to set the controller back to a known condition.
- Click Save to File.
- Select All Parameters.
- Save the file.
Set the battery limits
In Advanced Setup, open Peripheral Selection > Battery.

Peripheral Selection > Battery
- Set
Rated system voltageto the nominal voltage of your battery. - Set
Battery current limitto 100% as a starting value. Then, the rated motor power that you enter in the next section is the system limit for motoring. - Set
Regeneration battery current limitto a value from 20% to 30% as a starting value. The factory default is 10%, so you must increase it. This value keeps regenerative braking low until you tune it. - Click Save to Flash.
Both limits are percentages of the rated battery current, which the controller calculates from Rated motor power (Race mode PAS power) and Rated system voltage. Refer to Rated limits.
Note
If the battery voltage is below Rated system voltage, the controller gets to the battery current limit before the rated motor power. Thus, the controller starts to limit the output power. The controller does not measure the battery current. It calculates an estimate from the motor power, with an efficiency of 95%. This value gives a safe estimate.
If your battery has a BMS that communicates with the controller, set Battery management interface type. Refer to BMS. You can also do this step after the quick start.
Enter the motor ratings
In Advanced Setup, open Peripheral Selection > Motor Nameplate Ratings. To see all the parameters, scroll the upper-left panel.

Peripheral Selection > Motor Nameplate Ratings
- Set
Rated motor power (Race mode PAS power)andRated motor power (Race mode Throttle power)to the rated motor power from your system information. If you use the alternate (street) mode, also setRated motor power (Street mode PAS power)andRated motor power (Street mode Throttle power). - Set
Rated motor current. - Set
Rated motor speed. - Set
# of motor pole pairs. - Set
Gear ratio. - Click Save to Flash.
For the function of each value, refer to Motor setup.
Run motor discovery
DANGER
- The motor turns for up to 20 seconds with high current, at 25% of
Rated motor speedby default (50% in firmware before 6.016). - Make sure that all moving parts (for example, the motor, pedals, and wheels) can turn freely in the two directions.
- Make sure that the motor is attached tightly and that the wheels do not touch the ground.
To stop the motor, do these steps in this sequence:
- Set
Motor discover modeto 0 (0 is off). - Turn off the key-in. On a low-power controller, disconnect the key-in jumper.
- Disconnect the battery only if the other steps do not stop the motor. If you disconnect the battery while the motor turns, a voltage spike can cause damage to the controller.
Motor discover mode is in the lower-left panel of the motor page. The results appear in the Display Only panel.

Peripheral Configuration > Basic Motor (Sensored) after discovery of a sensorless motor. The Hall table stays at -1 because the motor has no Hall sensors.
In Advanced Setup, open Peripheral Configuration > Basic Motor (Sensored).
- Set
Motor position sensor typeto Hall Based. - In the lower-left panel, set
Motor discover modeto 9 (the option that starts "9 is an automatic sequence"). The controller measures the motor. Then it turns the motor for approximately 20 seconds. Make sure that the motor turns steadily in the correct forward direction. - When the motor stops, make sure that these values in the Display Only panel are correct:
autotune rated rpmis approximately equal toRated motor speed.autotune hall sector[0]toautotune hall sector[7]make a valid Hall table. The values 0 to 5 each occur one time, and -1 occurs two times.
- Click Save to Flash.
In Advanced Setup, open Peripheral Configuration > Basic Motor (Sensorless).
- Set
Motor position sensor typeto Sensorless. - In the lower-left panel, set
Motor discover modeto 9 (the option that starts "9 is an automatic sequence"). The controller measures the motor. Then it turns the motor for approximately 20 seconds. Make sure that the motor turns steadily in the correct forward direction. - When the motor stops, make sure that
autotune rated rpmin the Display Only panel is approximately equal toRated motor speed. - Click Save to Flash.
For encoder discovery, you must decrease the switching frequency and use user access level 1. Do the steps in the Encoder tab in Motor setup. The parameters are on Peripheral Configuration > Encoder.
If discovery fails or the results are not correct, refer to Motor setup troubleshooting. Do this also if the motor turns in the incorrect direction.
Set up the throttle
Connect the throttle to the evaluation harness. Refer to Throttle wiring and Pinout specifications.
- In Peripheral Selection > Command Inputs, set
Control command sourceto Remote. Then the motor does not turn while you calibrate the throttle. -
In Peripheral Configuration > Throttle, set
Throttle sensor sourceto the input that the throttle is connected to, for example Throttle.
Peripheral Configuration > Throttle
-
Close the throttle fully. Read
throttle voltage(or the voltage of the input that you use) in the Display Only panel. Enter this value inThrottle off voltage. - Open the throttle fully. Read the voltage again. Enter this value in
Throttle full voltage. - In Peripheral Selection > Command Inputs, set
Control command sourceto Throttle. - Click Save to Flash.
For the deadband, the fault range, and other throttle options, refer to Throttle.
Test the system
DANGER
From this step, the motor responds to the throttle. Make sure that the vehicle cannot move and that the wheels do not touch the ground.
- Open the throttle slowly. Make sure that the motor starts smoothly, and that its speed increases when you open the throttle more.
- Make sure that
throttle setpointon Peripheral Configuration > Throttle changes from 0 at closed throttle to 1 (100%) at full throttle. - Make sure that no faults show in the Faults and Warnings view.
- Click Save to File. Save a new parameter file of your setup that operates correctly.
If the motor does not respond to the throttle, refer to Throttle troubleshooting.
Next steps
The controller now operates the motor from the throttle. For more configuration, refer to the reference pages for your application: