Rated Limits
Introduction
BAC Controllers monitor system voltage, limit over current draw and limit regenerative current. In order to do so and protect your system, the following configuration guide must be followed.
Configuration
Under the Peripheral Selection
/Battery
tab, you should be able to configure the following parameters:
- Enter the battery's rated voltage in the
Rated System Voltage
parameter. This should not be the measured voltage at 100% SOC but the rated voltage of the battery itself. - Enter the maximum battery current limit as a % of rated motor current.
- Enter the
regeneration battery current limit
as a % of rated motor current.
Note
If a controller's Regeneration battery current limit
parameter is set to 0%. Even a slight rollback of a direct drive vehicle will not allow forward motion until the vehicle comes to a complete stop. To avoid this type of behaviour set this parameter to at least 20%.