Walk mode
Introduction
Walk mode is an auxiliary command source triggerable over network communication, for example via your display walk command.
This page will cover the setup and tuning of walk mode.
Setup
-
Enable
Features bit 11
Walk mode enable. -
Set
Walk mode signal source
to 4 / serial (display) -
Set
Vehicle jog speed
to limit walk mode speed.Note
Speed is only limited if in
Speed regulator modes
0 / Speed or 2 / Torque mode with speed limiting. `Speed Regulator Mode 1 / Torque mode is not speed limited.-
Regular speed regulation control loop applies.
-
Speed regulator Ki for Walk mode
andSpeed regulator Kp for Walk
mode can be used instead ofSpeed regulator Ki
andSpeed regulator Kp
for walk mode. Set to non-zero to use them.
-
-
Verify walk command works.
-
If using a display, enable walk command.
-
If sending value over network, write 1 to
Display walk command
to enable, and 0 to disable walk mode.
-
Application notes
This feature is only available with TE configuration
1 Pedal Bikes (ISO13849) "EN" as of firmware 6.017 and up.
This feature requires a heartbeat of faster than 0.4Hz.
Send Remote state command
a rolling counter on the high Byte to satisfy the heartbeat. For example: Low byte = 0 and High byte = Rolling counter from 0 to 255 on 100ms interval.
Low byte | Remote State Command | 0 = Off 1 = Idle 2 = Active |
High byte | Watchdog Counter | Rolling Counter from 0 to 255 |