Reverse
Introduction
When operating locally, using throttle or pedal inputs, it is possible to command the motor to go in reverse via a switch or a message over the network. This page describes the available inputs and how to configure the parameters accordingly.
Wiring
A single throw switch is typically used as the input source and connected to either Cruise/Digital Input 1 or _PFS/Digital Input 2. Since the digital inputs are pulled up, the switch would be connected between GND and
For network, a command must be sent to Remote Digital Commands bit 15
Enable reverse.
Note
For Firmware 6.018 and below, Cruise/Digital input 1 is the only input option.
In the following exmaple, the Reverse input is conencted to cruise as a single throw switch tying the digital input to ground when turned on.
Configuration
-
Enable
Features bit 1
Reverse enable on cruise -
Select the
Reverse Enable Source
(address 1936) (Firmware 6.019 and above) -
If in a speed limiting mode, limit the reverse speed via
Vehicle jog speed
-
Enable
Features bit 7
Reverse interlock disable if you wish to be able to switch to reverse without coming to a full stop first. -
Enable reverse and verify
ebike flags bit 8
Reverse is active:- Cruise/PFS: pull input to ground. E.g. close the switch.
- For network, a command to enable
Remote Digital Commands bit 15
Enable reverse must be sent (Firmware 6.019 and above)