Alternate Speed Power
Introduction
The BAC controllers have two configurable power and speed modes. The default mode is Race mode, the secondary mode is Street mode. You are in default mode if you do not configure alternate modes, and if you have, when your input is not active. For example, if you've set Cruise to be your input source, you are in default Race mode when the switch is open and in Street mode when the switch is closed connecting Cruise to ground.
Alternate mode inputs
Available input sources for alternate power and speed modes include Cruise/Digital input 1, PFS/Digital input 2, Brake 1/Analogue input 2, Brake 2/Analogue input 3, and remote pwr sw or remote spd sw by writing over the network to Remote Digital Commands bit 5
Alt Spd or Remote Digital Commands bit 5
Alt Spd respectively.
Alternate power mode setup
- Enable
Features bit 10
Alternate power limit enable. - Select your input source,
Alternate power switch source
. -
Enter your desired power limits for:
Rated motor power (Race mode PAS power)
2Rated motor power (Race mode Throttle power)
Rated motor power (Street mode PAS power)
2Rated motor power (Street mode Throttle power)
-
Note 1: We require
Race mode
power to be set higher thanStreet mode
power. - Note 2:
PAS Power
applies to pedal and all other power limits other than throttle. Consider it the default power.
Alternate speed mode setup
- Enable
Features bit 8
Alternate speed limit enable. - Select your input source,
Alternate speed limit switch source
- Enter your desired power limits for:
Vehicle maximum speed (Race mode PAS max speed)
Vehicle maximum speed (Race mode Throttle max speed)
Vehicle maximum speed (Street mode PAS max speed)
Vehicle maximum speed (Street mode Throttle max speed)