Faults
Faults Table
| Fault | Cause | Behaviour |
|---|---|---|
| Low Field Strength | Magnetic field either too weak or not present | Sensor will report 0º and 0%, appropriate fault codes 0x08 are set |
| Redundancy Fault | Disagreement between redundant sensors | Sensor will report 0º and 0%, appropriate fault codes are set |
| Sensor Link Fault | Internal sensor communication lost | Sensor will report 0º and 0%, appropriate fault codes 0x08 are set |
| Sensor Internal Fault | Numerous | Sensor will report 0º and 0%, appropriate fault codes are set |
| Travel Bounds Fault | Angle is outside the specified relative deadbands | Sensor will report measured and calibrated angles as usual but will report 0% relative travel, appropriate fault codes are set |
Clearing Faults
Faults are cleared by a power cycle or by sending a fault clear command (see Software Interface section for more information).