Walk Mode
Introduction
Walk mode is an auxiliary command source triggerable over network communication, for example, via your display walk command.
This page will cover the setup and tuning of walk mode.
Setup
-
Enable
Features bit 11Walk mode enable. -
Set
Walk mode signal sourceto 4 / serial (display) -
Set
Vehicle jog speedto limit walk mode speed.Note
Speed is only limited if in
Speed regulator mode0 / Speed or 2 / Torque mode with speed limiting.Speed regulator mode1 / Torque mode is not speed limited.-
Regular speed regulation control loop applies.
-
Speed regulator Ki for Walk modeandSpeed regulator Kp for Walk modecan be used instead ofSpeed regulator KiandSpeed regulator Kpfor walk mode. Set to non-zero to use them.
-
-
Verify walk command works.
-
If using a display, enable walk command.
-
If sending value over network, write 1 to
Display walk commandto enable, and 0 to disable walk mode.
-
Application Notes
This feature is only available with TE configuration 1 Pedal Bikes (ISO13849) "EN" as of firmware 6.017 and up.
This feature requires a heartbeat of faster than 0.4 Hz.
Send Remote state command a rolling counter on the high byte to satisfy the heartbeat. For example: Low byte = 0 and High byte = Rolling counter from 0 to 255 on 100 ms interval.
| Byte | Function | Notes |
|---|---|---|
| Low byte | Remote State Command | 0 = Off, 1 = Idle, 2 = Active |
| High byte | Watchdog Counter | Rolling Counter from 0 to 255 |